© 2009 Directed Electronics. All rights reserved.
Programming jumpers
AVISTART 4003
Input polarity jumper
ACTIVATION INPUT POLARITY
(-)
(+)
TACH THRESHOLD
On
LIGHT FLASH OUTPUT
O
(-)
(+)
*
*default setting
*
*
➢Light flash (+)/(-)
This jumper is used to determine the light flash output polarity. In the (+)
position, the on-board relay is enabled and the unit will output (+)12V
on the WHITE wire, H1/9. In the (-) position, the on-board relay is dis-
abled. The WHITE wire, H1/9, will supply a 200mA (-) output suitable
for driving factory parking light relays
Note:
For parking light circuits that draw 10 amps or more, the internal
jumper must be switched to a (-) light flash output.
P/N 8617
or a
standard automotive SPDT relay must be used on the H1/9 light flash
output harness wire.
➢Activation Input (+)/(-)
This jumper is used to determine the input polarity to activate the remote
start. In the (+) position the White/Blue H1/4 wire will require a (+)
pulse to activate the remote start. In the (-) position the White/Blue
H1/4 wire will require a (-) pulse to activate the remote start.