QRN4003 2011 -12
Programming System Features
The System Features Learn Routine dictates how the unit operates. It is possible to access and change most of the
feature settings using the Valet button.
1. Turn the ignition on, then off.
2. Select a Menu. Press and hold the Valet button. When the LED flashes once, Menu One has been se-
lected. Continue to hold the switch until the LED flashes twice. Menu Two has now been selected.Release
the Program switch after the desired Menu choice has been selected.
3. Choose. Within 10 seconds, press and release the Valet button the number of times corresponding to the
feature number you want to program. (See Features Menu section.)
Once the Valet button has been pressed and released the desired number of times, press it once more and
hold it. After a second, the LED will flash to indicate which feature you have accessed. For example, groups
of eight flashes would indicate access to the status output feature (Feature 8 of menu 2).
4. Activate Input. Each time the white/blue is pulsed, the LED will turn on or off indicating the feature setting.
If the feature has more than two selections, each time this input is pulsed the next available setting will be
picked. For example if 60 minute runtime is chosen, (Feature 2, Menu 2) the LED flashes 3 times.
5. Release. The Valet button can now be released.
Once a feature is programmed:
• Other features can be programmed within the same menu
• Another menu can be selected
• The learn routine can be exited if programming is complete
To access another feature in the same menu:
1. Press and release the Valet button the number of times necessary to advance from the feature you just pro-
grammed to the next one you want to program.
2. Then press the Valet button once more and hold it.
To select another menu:
1. Press and hold the Valet button.
2. After 3 seconds, the unit advances to the next menu, the horn honks and LED flashes indicating which menu
has been accessed.
The learn routine exits if any of the following occurs:
• The ignition is turned On
• There is no activity for 30 seconds
• The Valet button is pressed too many times
Bitwriter - Only Options
If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine has
previously been locked, it must be unlocked with Bitwriter® - this cannot be done manually with the Valet
button.
The Bitwriter® gives you access to a wider range of system options. These features and the adjustments that
may be programmed are described in the table below.
Menu Item Feature Default Options
1
Engine Runtime
12 min.
1-60 min.
2
Diesel start type
Off
Timed
3
Diesel start delay time (seconds)
15 sec
1-90 sec.
4
Virtual Tach Fine Tune
Not initialized
0 to 1 second in 50 millisecond
increments
5
Remote control programming
Unlocked
Locked
6
Feature Programming
Unlocked
Locked
Remote Start Shutdown Diagnostics
To perform shutdown diagnostics:
1. With the ignition Off, press and hold the Valet button.
2. Turn the ignition On and then back Off while holding the Valet button.
3. Release the Valet button.
4. Press and release the Valet button. The LED flashes to report the last shutdown for one minute or until the
ignition is turned on, as shown in the following table:
LED Flashes Shutdown Mode
1 flash Timed out
2 flashes Over-rev shutdown
3 flashes Low or no RPM, low battery (voltage and virtual tach modes)
4 flashes Transmitter shutdown (or optional push button)
5 flashes (-) Hood Shutdown (H3/4 GRAY)
6 flashes (+) Shutdown (H3/3 BROWN)
7 flashes (-) Neutral safety shutdown (H3/1 BLACK/WHITE)
8 flashes Wait-to-start timed out
Feature Menus
Default settings are in bold type.
Menu 1
Feature # Feature Opt. 1 Opt. 2 Opt. 3 Opt.4 Opt. 5+
1 Horn function
Off
Siren
20 mS
Siren
30 mS
Siren
40 mS
Siren
50 mS
2 Ignition con-
trolled lock
On
Off
3 Ignition con-
trolled unlock
On
Off
4 Doorlock out-
put duration
0.8 sec
.
3.5 sec. 0.4 sec.
5 Double pulse
unlock
Off
On
6 Double pulse
lock
Off
On
7 Factory Alarm
Disarm func-
tion
with unlock
Before unlock Remote start
only
8 Factory Alarm
Disarm Pulses
Single
Double
9 Comfort
Closure
Comfort
Closure 1
Off
Comfort
Closure 2
10 Panic
On
Off
Menu 2
Feature # Feature Opt. 1 Opt. 2 Opt. 3 Opt.4 Opt. 5+
1 Engine check-
ing
Virtual tach
voltage Off tachometer
2 Engine
Runtime
12 min
24 min 60 min
3 Park light
output
Pulsed
Constant
4 Cranking time
0.6 sec
.
0.8 sec. 1.0 sec. 1.2 sec. 1.4,
1.6,
1.8,
2.0,
4.0 sec
5 Activation
pulse count
1 pulse
2 pulses 3 pulses
6 2nd Ignition
behavior
Ignition
Accessory
7 Accessory
output
Off during
wait-to-start
On during
wait-to-start
8 2nd Status
behavior
Normal
Latch rear
defogger
Pulse rear
defogger
9 Anti-grind
On
Off
10 Diesel start
delay
Off
Timed 15 sec Timed 30 sec. Timed 45 sec.
11 Timer mode
run time
12 min
3 min 6 min 9 min
Bitwriters with a date code of 6a or older require an IC
upgrade (p/n 998M). Some bitwriters with a date code
of 6B do not require the IC upgrade, refer to tech tip #
1112 for more information.
The Bitwriter® (p/n 998U)
requires chip version 2.7 or
newer to program this unit.
See full Installation Guide for more
detailed information on this system.
Such information and more can be
found online at:
www.directechs.com
Logo, Directed Electronics w-driven.eps
Logo, Directed with designed in USA.eps
Logo, Directed with Distributed By.eps
Directed Logo Usage
Page view 1
1 2

Comments to this Manuals

No comments